Controls and Meters - Flow Control Specialists
HOME       ABOUT US       NEWS      CONTACT US       SITE MAP      
 
Flow Measurement
and Control Products
 
Hardware and
Software Integration
 
Control Panel Design
Assembly & Documentation
 
On-Site & In-House
Repair and Proving
 
Case Studies
NIAGARA
Magnetic
Turbine
Positive Displacement
Oscillating Piston
Electronics
Liquid Level
 
6600 Series Magnetic FlowmeterDownloads
6600 Magnetic Flowmeter

Ease of Installation & Maintenance: Grounding rings not required; No moving parts

Accuracy: High accuracy, +/- 0.5% of flow rate; Independent of fluid viscosity, density, temperature, or solids content.

Does not affect Process Conditions: Negligible pressure drop across flowmeter

MTX Turbine Flowmeters Downloads
MTX

Versatile
- Models 122 & 123 display continuous totalization
- Models 413, 433, & 444 display continuous totalization and provide a calibrated contact closure
- Models 420 & 421 display continuous totalization with the option of adding the 840 calibrated contact closure and/or the 860 calibrated digital pulse signal without removing the flowmeter from the line.

Durable
- Sealed register prevents condensation or fogging
- One internal moving part
- Multi-jet design ensures balanced forces and extends meter life


WPX Turbine Flowmeters Downloads
WPX Flowmeter

Saves Space
- very compact size
- lightweight

Reliable
- sealed register prevents condensation or fogging
- one internal moving part
- modular construction allows ease of service and field repair

Durable
- Add pulse transmitters without downtime
- Model 840 Pulser provides a calibrated contact closure
- Model 860 Pulser provides a calibrated digital pulse signal


Nutating Disc Meter Downloads
Nutating Disc Meter Liquid enters a precision-machined chamber containing a disc which nutates (wobbles). The position of the disc divides the chamber into compartments containing an exact volume. Liquid pressure drives the disc to wobble and a roller cam causes the nutating disc to make a complete cycle. The compartments are filled and emptied each cycle. The movements of the disc are transmitted by a gear train to a register/totalizer or pulse transmitter. Close clearances between the disc and chamber ensure minimum leakage for accurate and repeatable measurement of each volume cycle.

Oscillating Piston Meter Downloads
Oscillating Piston Liquid enters a precision-machined chamber containing an oscillating (rotating) piston. The position of the piston divides the chamber into compartments containing an exact volume. Liquid pressure drives the piston to oscillate and rotate its center hub. The movements of the hub are sensed through the meter cover by a follower magnet. Each revolution of the piston hub is equivalent to a fixed volume of fluid, which is indicated as flow by a register/totalizer. Close clearances between the piston and the chamber ensure minimum liquid slip for highly accurate and repeatable measurement of each volume cycle.
Manual

Model 3030 Batch Controller Downloads
3030 Batch Controller

The Model 3030 is a microprocessor based batch controller and flow rate indicator/totalizer that is capable of single or dual stage batch control. Two process parameters such as batch count and final batch quantity can be displayed simultaneously on the 16-character display. The Model 3030 has five control inputs, which when switched to ground, perform specific functions such as remote batch stop. Four open collector control outputs may be used to interface with remote devices such as relays, counters, and lights.


Model 1030 Indicator Downloads
1030F Indicator

The Model 1030F is a microprocessor based flow rate indicator/totalizer with a 4-20 mA output that is proportional to flow rate and RS-485 communications. Flow rate and total can be displayed simultaneously on the 16-character display. The Model 1030F has five control inputs, which when switched to ground, perform specific functions such as resetting the totalizer. Four open collector control outputs may be used to interface with remote devices such as relays, counters, and lights.


Model 1005 Pulse to DC Converter Downloads
1005 Pulse to DC Converter

The Model 1005 amplifies and conditions the contact closure or digital pulse signal from the Niagara flowmeters and converts it to a powered 4-20 mA output. The 4-20 mA signal is proportional to flow rate and can be used to interface with chart recorders, computers, or other instrumentation. The Model 1005 is factory calibrated with 4 mAs set at zero flow and 20 mAs set at the customer specified flow rate.


Ultrasonic Liquid Level Controller - 5600 SeriesDownloads
Liquid Level Controller Quick Config - Adjusts systems parameters and pre-calibrates unit without special software
Continuous Non-Contact Level Measurement - No contamination of material, no lost parts or cables
Sentry™ DSP - Provides stable and accurate reading under noisy process conditions
Built-in Optically Isolated Serial Port - Versatile interfacing for data collection, servicing and building large multi-vessel communications systems
NEMA-4X Enclosure - FRP or optional stainless steel offers the right protection for your environment